Welcome Customer !

Membership

Help

Beijing Juying Soaring Electronics Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Beijing Juying Soaring Electronics Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 401, Science and Trade Building, Shangdi Nankou, Haidian District, Beijing

Contact Now

Cloud series DAM0455 single network port

NegotiableUpdate on 09/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1、 Product features: DC7-30V wide voltage power supply; ◆ Input optocoupler isolation, relay output contact isolation; The communication interface supports WIFI and network ports; Supports standard Modbus protocol, as well as RTU and TCP formats;

Product Details

CHARACTERISTICS

DC7-30V wide voltage power supply; Input optocoupler isolation, relay output contact isolation; The communication interface supports WIFI and network ports; Supports standard Modbus protocol, as well as RTU and TCP formats; Equipped with flashing and breaking functions, it can include parameters in the command and operate the relay to automatically turn off after a period of time; Equipped with strobe function, it can control the periodic switching of relays;

2、 Product Features

5-way optocoupler input (5-24V); 4-channel relay output; 5-channel 12 bit resolution analog voltage input; Support baud rate: 2400480096001920038400 (can be modified through software, default 9600);

Intelligent self-control version features:

Timed control - customizable time control for year, month, day, hour, minute, and second, which can be looped;

Output Interlock - Customize the interlocking relationship between output channels;

Switch linkage - manual switch or switch triggered device is linked with control output;

Analog automatic control - customize the upper and lower limit thresholds of analog signals, and automatically control them after triggering;

Scene control - Customize complete logic control triggering conditions;

70 sets of rule settings - up to 70 sets of rule condition settings to meet various logical requirements.

3、 Version Description

① Normal version: The default input and output of the device are independent of each other and have no relationship.

② Intelligent self-control version:

Timed control - customizable time control for year, month, day, hour, minute, and second, which can be looped;

Output Interlock - Customize the interlocking relationship between output channels;

Switch linkage - manual switch or switch triggered device is linked with control output;

Analog automatic control - customize the upper and lower limit thresholds of analog signals, and automatically control them after triggering;

Scene control - Customize complete logic control triggering conditions;

70 sets of rule settings - up to 70 sets of rule condition settings to meet various logical requirements.

4、 Main parameters

5、 Interface Description

6、 Communication wiring instructions

1. Communication connection

DAM Ethernet devices need to be in the same network segment as the PC IP. When both wired and wireless networks are connected to the PC, disable the wireless network and connect to the wired network. Configure device parameters and operating modes.

2. WiFi reset instructions: The small black button on the left side of the network port is the reset button.

Press and hold the reset button 6S, the Ethernet port light will turn off once and then display again, indicating a successful reset. After the first reset, the device will become a dynamic IP. Continue to press and hold the reset button 6S, the Ethernet port light will turn off once and then display again, and the device will become a static IP. The default static IP is 192.168.1.232.

3. Architecture Description: The device uses a wide area network based on the Internet for remote communication, and communicates with our cloud server ems.jydtu.com through configuration parameters, with port number 60001.

7、 Quick instructions for use

1. Connect the device to the router (connected to the external network) using an Ethernet cable; 2. Open the Ethernet configuration software on the PC computer to configure parameters; 3. Install cloud platform app software on mobile phones; 4. Add devices through the cloud platform for testing purposes.

8、 Input/output wiring

1. Schematic diagram of active switch wiring

2. Schematic diagram of passive switch wiring

3. Relay wiring instructions

4. Analog wiring diagram

The power supply in the following figure is for sensor power supply. AI1-AI5 are connected to the sensor signal positive, ACOM - is the sensor signal negative, and ACOM+is not used. The relationship between the AI data collected by the device and the actual input value: actual value=return value * 0.001

two-wire system

three-wire system

four-wire system

9、 Equipment parameters and working mode configuration

1. Network configuration

The single network port version device can be configured for parameters and working modes through the Ethernet configuration software. For detailed configuration methods, please refer to the "Juying Cloud Platform Single Network Port Version User Manual" document;

Download link:User Manual for Juying Cloud Platform Single Network Port Version

Ethernet configuration software download address:Ethernet configuration software

2. Equipment address

2.1 Introduction to Equipment Address

The default address for DAM series devices is 0, and communication using broadcast address 254 is not possible with 0. Device address=dip switch address+offset address. Note: This device does not have a dip switch, so the device address=offset address.

2.2 Setting of Equipment Address

① Use JYDAM debugging software to set up, software download address:JYDAM Debugging Software

② InWrite the device address that needs to be set and click on itOnce the settings are complete,The address of the current device displayed here.

3. Working mode

① Normal version: The default input and output of the device are independent of each other and have no relationship.

② Intelligent self-control version: The correspondence between switch input (DI) and analog input (AI) and relay output (DO) requires the use of DLC configuration software or direct configuration on cloud platform software. DLC configuration software download address:Click to download

10、 Unique Device ID Number

To use the Juying Cloud platform software, it is required that the DAM device has a unique ID number. There are two ways to obtain the unique ID number: 1. Scan the QR code to obtain it. Use your phone to scan the QR code on the device casing or packaging casing to obtain the unique ID number, as shown below:

11、 Platform Software Description

Juying Cloud Platform is a network platform software developed by our company, which includes mobile APP platform software and web version platform. The mobile APP software includes two categories: Android and IOS. The platform is designed for our company's DAM series network version devices and GPRS version devices, aiming to provide users with remote control output (relay, switch quantity), analog quantity (4-20mA, 0-10V, 0-5V) acquisition, switch quantity acquisition and other services, greatly facilitating user needs. The server is provided by our company, and customers can use it with confidence.

For specific operation instructions, please refer to the document 'User Manual for Juying Cloud Platform Single Network Port Version';

Download link:User Manual for Juying Cloud Platform Single Network Port Version

12、 Development documentation description

1. Communication Protocol Description: This product supports standard Modbus instructions. For detailed instruction generation and parsing methods, please refer to the register table in this article in conjunction with the "MODBUS Protocol Chinese Version". Download link for Modbus protocol manual:Modbus 20POLL Software and User Manual

2. Modbus Register Description

Coil register address table:

Note:

① Modbus device instructions support the following Modbus addresses: 00001 to 09999 are discrete outputs (coils), 10001 to 19999 are discrete inputs (contacts), 30001 to 39999 are input registers (usually analog inputs), 40001 to 49999 are hold registers (usually storing device configuration information), using a 5-bit code format, with the first character determining the register type and the remaining 4 characters representing the address. Address 1 starts from 0, such as 00001 corresponding to 0000.

② Table of baud rate values correspondence

③ Relay status can be queried through address 30002 or address 00001--00002, but control can only use address 00001--00002. The data length of 30002 address is 16 bits. It can represent up to 16 relays. The corresponding results are as follows:

The bit 8 of the data in register 30002 is the same as the data in register 00001. Similarly, the same goes for optocoupler input. The bit8 and bit9 of register 30003 and registers 10001 and 10002 correspond to the specified hardware. The register address follows the PLC naming convention, where the real address is obtained by removing the highest bit and then subtracting one. reference material:reference material

3. Instruction generation instructions: Instructions can be obtained by checking the debugging information in the "Juying Soar DAM Debugging Software".

Instruction generation instructions: For instructions not listed in the table below, users can generate them themselves according to the Modbus protocol. For reading and writing relay coils, it is actually reading and writing coil registers in the Modbus register. The address of the relay register has been explained in the previous text, and users only need to generate read and write instructions for register operations. For example, reading or writing the status of relay 1 is actually a read/write operation on the coil register 00001 corresponding to relay 1.

4. Instruction List

5. Instruction Explanation

5.1 Relay output

Control one relay (taking the first one as an example, refer to this example for other channels), if any byte changes, the CRC check bit will also change accordingly.

Sending code: FE 05 00 00 FF 00 98 35

Relay card return information:

Return code: FE 05 00 00 FF 00 98 35

5.2 Relay Status

Query 4-channel relays

Sending code: FE 01 00 00 04 29 C6

Relay card return information:

Return code: FE 01 00 61 9C

5.3 Optocoupler input

Query optocoupler

Sending code: FE 02 00 00 00 05 AC 06

Optocoupler return information:

Return code: FE 02 01 50 5C

5.4 Analog quantity query

The relationship between the obtained analog data and the actual input value is: actual value=return value * 0.001

Query analog quantity AD word

Sending code: FE 04 00 00 00 05 24 06

Simulated return information:

Return code: FE 04 02 00 00 AD 24

5.5. Flash on/off command

Analysis of Flash Open and Flash Close Instructions

Flash development code: FE 10 00 03 00 02 04 00 04 00 0A 41 6B

Flashing sending code: FE 10 00 03 00 02 04 00 02 00 14 21 62

Return code: FE 10 00 03 00 02 A5 C7

5.6. Fully open and fully close command

Analysis of fully open and fully closed commands

Full development code: FE 0F 00 00 04 01 FF 31 D2

Total disconnection sending code: FE 0F 00 00 04 01 00 71 92

Full open return code: FE 0F 00 00 04 40 07

Total disconnection return code: FE 0F 00 00 04 40 07

13、 Technical Support Contact Information

Contact phone number: 4008128121, 010-82899827/1-803

Contact QQ: 4008128121