CGZ heating type pipeline dehumidifier

NegotiableUpdate on 04/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Name: CGZ Heating Type Pipeline Dehumidifier Model: CGZ50 Brand: Zhongyou Brand Dehumidifier Series Description: Product Features: 1. Flexible Vortex Compressor, High Efficiency, High Reliability, and Quiet Operation 2. Centrifugal Fan

Product Details

Product Name CGZ heating type pipeline dehumidifier
Model: CGZ50
Brand: Zhongyou brand dehumidifier series
Instructions: Product Features:
1. Flexible scroll compressor, high efficiency, high reliability, and quiet operation
2. Centrifugal blower, high efficiency, low vibration, and low noise
3. External balanced thermal expansion valve, mature technology, high reliability, and strong adjustability
4. Electric three-way valve and electric actuator, reliable and durable
5. Reasonably utilize and regulate the condensation waste heat to heat the treated air, saving energy and environmental protection
6. Stainless steel plate condenser has a small volume, high heat transfer coefficient, and strong anti fouling ability
7. It integrates heating and dehumidification, temperature regulation and dehumidification, and cooling and dehumidification functions*
8. Steel structure form, higher rigidity and strength, firm and durable
CGZ升温型管道除湿机
1There are various structural types of pipeline dehumidifiers
Conventional dehumidifiers come with built-in fans, which are easy to install and can be divided according to the air inlet and outlet methods:a.Forward air (grille return air), front air outlet (hood supply air),b.Rear inlet air (flange return air), top outlet air (flange inlet air),c.There are three types of air: forward air (grille return air) and top air (flange supply air). The pipeline dehumidifier does not come with a fan and needs to be equipped with a separate fan box. When facing the control panel, the air intake direction of the unit can be divided into two types: left inlet and right inlet.50-150kg/hThe pipeline dehumidifier can also provide detachable units for easy installation and transportation
2
The pipeline dehumidifier has complete functions
Both conventional dehumidifiers and pipeline dehumidifiers have three types of functions: heating type, temperature regulating type, and cooling type. Among them, heating dehumidifiers are mainly used for dehumidification and do not have cooling function, so they are suitable for dehumidification places without temperature requirements; The temperature regulating dehumidifier integrates dehumidification and cooling functions, and its cooling capacity is adjustable, making it particularly suitable for dehumidification places with large changes in thermal load. A cooling dehumidifier has a cooling function while dehumidifying, but its cooling capacity cannot be adjusted, making it suitable for dehumidification situations with high heat loads and no requirements for relative humidity.
3
Pipeline dehumidifier compressor and cold matching
Products used for compressors and main refrigeration components; Through scientific and rational optimization design of the refrigeration system, the unit has low noise, reliable operation, and high energy efficiency.
4
Pipeline dehumidifier heat exchanger
The water side heat exchanger is a shell and tube heat exchanger, using high-efficiency heat exchange tubes; The air side heat exchanger is a copper tube covered aluminum fin heat exchanger, which is imported from the United StatesOAKManufacturing of heat exchanger CNC production line. The heat exchanger has a compact structure, good pressure resistance, and high heat transfer efficiency
5
Environmentally friendly working fluid for pipeline dehumidifier
The concept of "green" units is adopted to meet the requirements of eliminationCFCThe national program for working fluids requiresR22Refrigerants are beneficial to the Earth's environment. The company can also customize according to user requirementsR407cTheR134awaitHFCMA high-quality dehumidifier.
6
Shell of pipeline dehumidifier
40kg/h
The following units adopt high-strength aluminum profile frames that are popular both domestically and internationally,50kg/hThe above units adopt steel profile frames; The bent parts are made in JapanAMADACNC equipment processing has excellent appearance quality. The unit adopts an assembled structure, which is compact, aesthetically pleasing, and highly modern.
7
Control mode of pipeline dehumidifier
The heating and cooling dehumidifiers are controlled by professional microcomputers; The temperature regulating dehumidifier adopts a high-performance programmable controller(PLC)Controlled with a Chinese text display, it has good reliability and high control accuracy. As long as the user sets the required temperature and humidity control range, the unit can automatically operate in the humidity priority mode.
8
Network functions that can be selected for pipeline dehumidifiers
The crew connects the equipment to the remote computer through a modem, utilizingINTERNETPerform data exchange, remote monitoring and fault analysis of the unit to help you quickly and accurately predict and troubleshoot faults. You can also usePROFIBUSThe bus realizes the group control function of the local area network dehumidifier.
9
Multiple protections for pipeline dehumidifiers
The unit is equipped with overload, short circuit, phase loss, overheating, high voltage, low voltage and other protections, and can also be optionally equipped with fan, water pump, and fire damper interlock protection.
Pipeline dehumidifier/Technical specifications of explosion-proof pipeline dehumidifier<2>

type number

sex can

CGZ50

CGZ60

CGZ75

CGZ90

CGZ100

CGZ120

BCGZ50

BCGZ60

BCGZ75

BCGZ90

BCGZ100

BCGZ120

dehumidification capacity

kg/h

50

60

75

90

100

120

refrigeration capacity

kw

81.6

98

122.4

147

165

204

electricity source

380VThe50HzThree phase four wire system

merit rate

(including fan)kw

28

36

40

50

55

65

wind quantity

m3/h

14000

18000

22000

25000

28000

32000

wind block

Pa

220

compressor

class type

fully enclosed

power

kw

22.4

27.2

33.8

41.3

45

51

refrigerant

type

R22orR407c

Throttle method

External balance thermal expansion valve

charge amount

kg

20

24

30

36

40

48

outside form

ruler inch

long

mm

2000

2400

2400

2400

3000

3000

lenient

mm

1000

1000

1000

1200

1600

1600

tall

mm

2000

2250

2250

2650

2650

2650

heavy quantity

kg

550

650

800

950

1100

1350

Note:CGZFor conventional heating type pipeline dehumidifiers,BCGZExplosion proof heating type pipeline dehumidifier