-
E-mail
781801536@qq.com
-
Phone
13165062660
-
Address
No. 30 Xianshan East Road, Chengyang District, Qingdao City, Shandong Province
Qingdao Rongguang Electronic Technology Co., Ltd
781801536@qq.com
13165062660
No. 30 Xianshan East Road, Chengyang District, Qingdao City, Shandong Province
QingdaoRongguang Electronic Technology Co., Ltd
Direct person in charge of product sales: An Chao
131 - 6506 - 2660
Please feel free to call for consultation at any time. Thank you
RGYQ-1 Heating and Dehumidification Smoke Samplingrod
RGYQ-1 Heating and Dehumidification Smoke Samplingrod
Product OverviewBoiler pipeline heating dehumidification flue gas sampling gun
RGYQ-1 Heating and Dehumidification Smoke SamplingrodMainly used for extracting smoke from fixed pollution sources, this smokerodThe front-end filter filters out smoke and dust. The collected gas is heatedrodThe body prevents condensation of water and undergoes rapid cooling through cooling to prevent adsorption and loss of pollutants from the flue gas source. It can be widely applied in fields such as environmental protection, health, labor, safety supervision, military, scientific research, education, etc.
Execution standardsBoiler pipeline heating dehumidification flue gas sampling gun
HJ/T47-1999 Technical Conditions for Smoke Samplers
Features
samplingRod rodReasonable body structure and simple appearance.
samplingrodadoptsamplingTube heating.
samplingrodThe backend adopts dual stage refrigeration.
samplingrodUsing rubberwood handles for easy operation.
3um titanium filter cartridge * filters particulate matter in flue gas without adsorbing SO2 and other gases.
technical indicators
Main parameters |
parameter range |
|
|
samplingrodlength |
1.0 meter |
|
|
Pitot tube coefficient |
0.84 |
|
|
Smoke temperature sensor (Pt100) temperature |
(0~500)℃ |
|
|
Requirements for measuring hole diameter |
Ф45mm |
|
|
samplingrodrefrigeration temperature |
4℃ |
|
|
heating temperature |
(130 ± 10) ℃, adjustable |
|
|
working power |
240W |
|
|
Working Voltage |
24V |
|
|
Qingdao Rongguang Electronic Technology Co., Ltd. provides technical support and comprehensive after-sales service for this instrument!
RGCY-1SL fixed pollution source sulfuric acid mist samplingpipe
Product Overview
RGCY-1SLSampling of sulfuric acid mist from fixed pollution sourcesrodMainly used for collecting sulfuric acid mist samples from fixed pollution source emissions. the samplingrodofrodhead androdThe body adopts constant temperature heating technology to prevent condensation and prevent the adsorption of sulfuric acid mist samples. Among them, solid sulfuric acid mist is used3Number filter cartridge collection, collection of gaseous sulfuric acid mist using reagent bottles, and measurement of smoke flow rate, smoke temperature, and other parameters during sampling; It can be widely applied in departments such as environmental protection, health, labor, safety supervision, scientific research, and education.
execution standard
HJ544-2016Determination of Sulfuric Acid Mist in Waste Gas from Fixed Pollution Sources - Ion Chromatography Method
GB/T16157-1996Sampling method for particulate matter and gaseous pollutants in exhaust from fixed pollution sources
HJ/T48-1999Technical Conditions for Smoke and Dust Samplers
Product Features
Applicable to domestic productionFilter cartridge 3, gaseous sulfuric acid mist is collected using two 250ml absorption bottles connected in series.
Multiple specifications of sampling nozzles can be used together to meet the collection needs of different flow rates.
Equipped with adjustable height tripod for supporting samplingrodAnd absorption bottles.
Equipped with an absorption bottle electric refrigeration box that can hold a mixture of ice and water, with a controlled temperature of(3~5)℃.
rodhead androdThe body adopts full process constant temperature heating technology, which does not produce condensed water and prevents the adsorption of sulfuric acid mist samples.
rodThe body length can be customized,rodThere are scale markings outside the body, which can be used to view the size of the flue.
rodThe body adopts full heating and temperature control throughout the process0~199)℃At any point, adjustable.
The smoke temperature sensor adoptsPt100Adopting standardsSType skin care tube.
technical indicators
Main parameters |
parameter range |
Main parameters |
parameter range |
samplingrodlength |
1.5Rice (customizable) |
heating temperature |
(0-199)℃, adjustable |
Pitot tube coefficient |
0.84 |
Smoke temperature sensor(Pt100)Temperature |
(0-500)℃ |
Requirements for measuring hole diameter |
≥Ф75mm |
working power supply |
DC24V |
Sampling nozzle diameter |
4mmThe5mmThe6mm 8mmThe10mmThe12mm |
working power |
150W |
Absorption bottle |
250ml |
Number of absorption bottles |
2a |
QingdaoRongguang Electronic Technology Co., LtdThe company provides technical support and comprehensive after-sales service for this instrument!