Blackbody Radiation Source IR563- High Temperature Blackbody Radiation Source - Surface Source Blackbody Product Description:
Blackbody Radiation Source IR563- High Temperature Blackbody Radiation Source - Surface Source BlackbodyInfrared Systems Development Corporation (ISDC)The ideal radiation source for the near (1-3 um), medium (3-8), and far (8-30+um) infrared bands, as the industry standard 1000 º C blackbody, has a history of more than 30 years and can provide excellent services for infrared applications in the entire industry. Adopting a 20 º conical concave conical structure, the surface emissivity and cavity aspect ratio are combined to provide blackbody radiation through multiple reflections, absorption, and re emission of its thermal energy. The thermal energy of the chamber is provided by a ceramic sealed heating coil, which can uniformly heat the chamber cylinder to a temperature of 50 º C to 1050 º C.

Working Principle:
Any object that emits radiation towards its surroundings as long as its temperature is above absolute zero is called temperature radiation. As long as its temperature is above absolute zero, it still needs to absorb radiation energy from the outside. Blackbody radiation sources mainly measure the temperature of an object through the infrared energy emitted by the object, which is generally divided into high temperature, medium temperature, and low temperature. They are commonly used in the industrial and medical industries, mainly for calibrating radiation measuring instruments such as infrared radiation thermometers to improve the accuracy of measurement results. Blackbody radiation sources mainly use infrared radiation thermometers or other radiation blackbody measuring instruments to test and compare the temperature of the blackbody cavity, in order to calibrate other measuring instruments such as infrared radiation thermometers.
The blackbody cavity of a blackbody radiation source is a blackbody, and the temperature of the blackbody cavity is controlled by the temperature controller of the radiation source. The chamber temperature of a standard radiation source can be set between 30 degrees Celsius and 550 degrees Celsius, and any temperature point can fluctuate up or down within 0.1 degrees Celsius. If you want to display the actual radiation temperature of the object being measured, you need to read the display screen inside the radiation source cavity, so that you can obtain the radiation temperature of the object being measured. The display screen of a blackbody radiation source is installed inside the cavity of the radiation source, which enables calibration of radiation measuring instruments such as infrared radiation thermometers.
Product Highlights:
Scope of application:
Technical Specifications:
Upgrade options: