Welcome Customer !

Membership

Help

Saifei (China) Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Saifei (China) Co., Ltd

  • E-mail

    biosafer@qq.com

  • Phone

  • Address

    Jingang Science and Technology Innovation Park, No.1 Kechuang Road, Qixia District, Nanjing City, Jiangsu Province

Contact Now

Biosafer-30AS Ultra Pure Water Machine

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Introduction Usage Technical Support Biosafer-30AS Ultra Pure Water Machine Process Features: Based on the design concept of "layer by layer protection, step by step filtration", pre-treatment is configured according to the source water condition, with stronger targeting; Flexible selection of single-stage or two-stage reverse osmosis processes is more reasonable and economical to use; Dow low-pressure RO membrane from the United States, with a desalination rate of ≥ 98%, is used in combination with automatic cleaning and manual flushing to ensure long-term and efficient operation; The German Heraeus dual wavelength ultraviolet lamp and the American AquaBest digestion instrument can efficiently sterilize and degrade organic matter; Rohm Haas nuclear grade deep treatment polishing mixed bed purification and ultra pure unit water quality resistivity reaches 18.25 Μ Ω· cm@25 ℃; According to usage requirements, imported ultrafiltration membranes and degassing membranes are selected to thoroughly filter out heat sources, soluble gases, and ultra pure water quality. High precision terminal microporous filters are also selected. Functional features: An integrated system for producing pure and ultrapure water using tap water as the water source. Four user password protection function. Real time monitoring of RO and UP water quality operation status. Complete management functions such as RO pure water and ultra pure water production, system water intake, system circulation, and disinfection. The ultra pure water system has built-in circulation settings to prepare the best required UP water quality. The ultrapure water circulation system can be freely started and turned off to maintain a low bacterial contamination state. Adopting imported RO membrane from Dow DOW in the United States. Fully automatic RO membrane anti scaling flushing program, manual/automatic flushing time can be set to extend the service life of RO membrane. Complete waterless protection, high-pressure water filling, etc .....

Product Details

  • Biosafer-30AS Ultra Pure Water Machine

    Process characteristics:

    according toLayer by layer protection, filtering step by stepThe design concept is to configure pre-treatment according to the source water conditions, which is more targeted; Flexible selection of single-stage or two-stage reverse osmosis processes is more reasonable and effectiveMore economical; Dow Low Voltage in the United StatesROMembrane, desalination rate≥98%The system combines automatic cleaning and manual flushing to ensure long-term and efficient operation; Heraeus GermanyHerauesDual wavelength ultraviolet lamp and the United StatesAquaBestA digestion instrument that can efficiently sterilize and degrade organic matter; Rohm and HaasRohm HaasNuclear grade deep processing polishing mixed bed purification and ultra pure unit water quality resistivity and reach18.25ΜΩ· cm@25 ℃According to usage requirements, imported ultrafiltration membranes and degassing membranes are selected to thoroughly filter out heat sources, soluble gases, and ultra pure water quality. High precision terminal microporous filters are also selected.


    Functional features:

    An integrated system for producing pure and ultrapure water using tap water as the water source.

    Four user password protection function. Real-time MonitoringROandUPWater quality operation status.

    perfectROManagement functions such as pure water and ultrapure water production, system water intake, system circulation, and disinfection.

    Ultra pure water system with built-in circulation settings for optimal preparationUPWater quality requirements. The ultrapure water circulation system can be freely started and turned off to maintain a low bacterial contamination state.

    Adopting Dow from the United StatesDOWimported with original packagingRODiaphragm. fully automaticROMembrane anti scaling flushing program, manual/Automatic flushing time can be set and extendedROMembrane service life.

    Complete water free protection, high-pressure water full protection functions, and fault alarm functions.

    Complete historical alarms, historical water intake records, and consumable life management functions, displaying consumable usage time and automatically reminding replacement upon expiration.

    Water quality detection sensor resistance pool constant:0.01-1Temperature sensitivity±0.1℃, possessing25℃Automatic temperature compensation function

    Equipped with analog pressure sensors and analog liquid level sensors, it can directly display the inlet pressure and water tank storage capacity.

    Ultra large capacity integrated two column ultra purification column module. The whole body column adopts food gradePPMaterial, no adhesive, no impurities precipitated. Original imported American Rohm and Haas electronic grade interiorUP6150Type, semiconductor gradeUP6040Core grade polishing resin, the highest effluent quality can reach18.25MΩ·cm.

    Adopting Heraeus from Germany(Heraeus)185/254nmDual wavelength ultraviolet sterilization. of which254nmThe energy contained in spectral lines can effectively destroy microorganisms, such as bacteria and virusesDNAMolecular structure, achieving the purpose of sterilization;185nmThe spectral lines can also decompose organic molecules in water and ultimately oxidize them to carbon dioxide, effectively removing themTOC.

    Adopting low voltage24VDCMain power supply, separated layout of water and electricity, in compliance with safety regulations, high-strength engineering plastic chassis, to prevent corrosion and rust.

    Ultra low radiation. Adopting advanced electromagnetic compatibility design, it has strong anti-interference ability and low noise.


    Working conditions:

    Water source: Urban municipal tap water(TDS≥300Enhanced pre-processing units are added to the system;

    Temperature:545℃

    Source water pressure:15Kg/cm2

    Power Supply:220V 50Hz

    power3080W

    Technical Parameter

    Water production capacity (25 ℃): 30L/h
    Pure water quality: conductivity≤0.5μS/ cm@25 ℃The water quality standard is superior to the third level water standard of China National Laboratory Water (GB6682-2008)
    Ultra pure water quality: conductivity ≤ 0.055 μ S/ cm@25 ℃; Electrical resistivity 18.25 Μ Ω· cm@25 ℃, the water quality standard is better than the first-class water standard of China National Laboratory Water (GB6682-2008)
    Water intake flow rate: RO pure water: 2L/min UP ultra pure water: 1.8L/min
    Heat source:/
    TOC:<10ppb
    Microorganisms:<1cfu/ml
    Microparticle: (greater than 0.2 μ m) Content:<1/ml
    Screen size: 4.3 inches

    Dimensions: length x width x height: 455 x 535 x 515mm


    remarks:

    This product has obtained CE certification.


    Related products:

    model Biosafer-5AS Biosafer-10AS Biosafer-20AS
    Biosafer-30AS Biosafer-40AS
    water source Municipal tap water Municipal tap water
    Municipal tap water
    Municipal tap water
    Municipal tap water
    water yield 5L/h
    10L/h
    20L/h
    30L/h
    40L/h
    Pure water quality
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Ultra pure water quality
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    RO water/ultrapure water intake flow rate 2/1.8 L/min 2/1.8 L/min
    2/1.8 L/min
    2/1.8 L/min
    2/1.8 L/min
    heat source / /
    /
    /
    /
    TOC <10ppb
    <10ppb
    <10ppb
    <10ppb
    <10ppb
    microorganism
    ﹤1cfu/ml
    ﹤1cfu/ml
    ﹤1cfu/ml
    ﹤1cfu/ml
    ﹤1cfu/ml
    Micro particles (larger than 0.2 μ m) ﹤1/ml
    ﹤1/ml
    ﹤1/ml
    ﹤1/ml
    ﹤1/ml
  • Application standard level experiments, preparation of high-purity standard solutions, quantitative analysis, blood testing, toxicity testing, preparation of buffer solutions, atomic absorption/emission spectroscopy, liquid chromatography, gas chromatography, etc.
  • Selection method of laboratory pure water machine

    Working principle of laboratory pure water machine

    Analysis of Common Laboratory Malfunctions

    Purification methods for water