MC-3000F/N coating thickness gauge(Automobile paint film thickness gauge)Equipped with two types of probes, Fe probeMeasurement using magnetic induction methodNon magnetism on ferromagnetic materialsThickness of coating, NF probeUsing electricityeddy currentLegal measurementNon-conductive on conductive metalsThe thickness of the coating.
This instrument uses magnetic thickness measurementTwo thickness measurement principles: eddy current thickness measurement and eddy current thickness measurement,alreadyCan be conveniently and non destructively measuredNon magnetic coating on magnetic materialsthicknessIt can also measure the thickness of non-conductive coatings on conductive substrates, greatly increasing the application range of coating thickness gauges. the instrumentWidely used in industries such as machinery, automotive, shipbuilding, petroleum, chemical, electroplating, spray painting, enamel, plastics, etc.
*Critical thickness: workpiecematrixWhen the thickness is greater than 1mmThe measurement of coating thickness is not affected by the thickness of the substrate.
1. Measurement:The instrument is equipped with two types of measuring probes. Fe probemeasurementNon magnetism on ferromagnetic materialsThickness of coating, NF probemeasurementNon-conductive on conductive metalsThe thickness of the coating.
2. Data management:Manage stored data through grouping. There are a total of 6 groups, each containing 99 pieces of data. You can view, delete, print, and communicate any set of data.
3. Measurement mode:There are two types of measurement modes: conventional measurement mode and monitoring measurement mode. We can provide users with different usage methods in different work sites to meet their needs.
a、 Conventional measurement
During measurement, the instrument only displays basic information of the measurement data, which can meet the basic measurement needs of users.
b、 Small value capture
When measuring data, the instrument will automatically capture small measurement values. If the factory acceptance is based on the small thickness value of the sample as the inspection standard, then this measurement mode is undoubtedlygoodThe choice.
c、 Statistical measurement
In this mode, the function bar of the instrument will display the maximum, minimum, average, and measurement times of the measurement data simultaneously. Provide users with more intuitive and convenient data analysis, thereby enabling real-time observation of the quality of on-site workpieces.
d、 Monitoring and measurement
In this mode, users can monitor the thickness of the workpiece in real-time by setting the upper and lower alarm limits. Once the measurement data exceeds the upper and lower limits, the instrument will display an over limit prompt symbol and emit a rapid alarm sound to alert the user. At the same time, users can also set the baseline to set a standard value and monitor the deviation between the measured value and the standard value at all times.
4schoolAccurate method:According to the on-site situation, users can choose zero point calibration, two-point calibration, or system calibration to ensure measurement accuracy.
5. Beep notification: During the operation, there will be a beep sound to alert the user.
6. Shutdown: There are two ways to shut down: automatic shutdown and manual shutdown.
7. Backlight: There are three options: backlight on, backlight off, and automatic backlight.
8. Instrument information: You can view the software version, probe information, and manufacturer information of the instrument.
9. System initialization: When the instrument system is disrupted due to misoperation or other external reasons, users are allowed to restore it to its factory state.
10Under power indication:On the top left of the instrument screencornerThe location,Display "
"Indicates that the battery voltage is low and needs to be replaced in a timely manner to avoid affecting use; display"
"Indicates that the battery voltage is normal.
For newly purchased instruments, please refer to "Attachment 1 Instruments and Accessories" to check if the relevant accessories are complete. Please contact the manufacturer promptly when incomplete; If the instrument is damaged, do not use it and contact the manufacturer as soon as possible.
A、 Please place the positive and negative terminals of the battery correctly in the direction indicated by the symbols inside the battery compartment.
B、 When plugging or unplugging the probe, please grip the connector on the probe wire and do not directly grip the probe wire. It is strictly prohibited to rotate the connector to avoid damaging the probe.


measurement range |
F1.2:0-1.25mm,N1.2:0-1.25mm |
Measurement Mode |
Simplified mode, monitoring mode, statistical mode, * small value capture |
Measuring principle |
Magnetic induction and eddy current |
display precision |
0~100μm: 0.1μm; 100~999μm: 1μm; 1mm~1.25mm: 0.01mm |
Probe connection method |
Split type wire connection (non replaceable) |
Operating temperature |
Relative humidity: ≤ 90%; Temperature: -10 ℃~+40 ℃ |
temperature compensation |
Equipped with Sci Tech's "phase-locked loop" technology |
language |
Built in Chinese and English |
measure speed |
Customers can choose between single measurement and continuous measurement speeds according to different application scenarios |
power supply |
Two AA batteries |
host size |
150mm(L)*68mm(W)*33mm(H) |
weight |
220g (including battery) |