Calculate and transmit liquid flow in pipelines and rectangular open channels.
Product Details

Area flow meter can monitor the flow of open channels, partially sewage filled pipes, and overflow pipelines without sinks or weirs. *Suitable for flow monitoring of municipal water, mixed water, untreated sewage, and irrigation water. The streamlined ultrasonic sensor utilizes an immersed ultrasonic sensor to continuously measure the flow velocity and liquid level in the channel. The electrode does not scale and is corrosion-resistant. Can be installed in turbulent and fast currents.

Instructions
Electronic circuit protection: Waterproof and dustproof grade NEMA 4X (IP66) polycarbonate shell: shiny and shatterproof.
Accuracy: Liquid level: ± 0.25% of full scale Flow rate: ± 2% of the reading. Repeatability and linearity: ± 0.1%
Display: A 4-digit LCD screen with a large screen; Menu/Status/Cumulative: 16 digit display
Programmable: The menu selection option is a 3-button keypad. Set password to protect calibration parameters
Input power supply: 100-130VAC 50/60Hz, maximum 7.5 watts
Output: Two isolated 4-20mA outputs, load: 1000 ohms. (Flow rate, head, flow velocity programmable)
Control relays: 3 control relays, forming a "C" dry contact, rated 5A SPDT: programmable process proportional pulse (sampler/accumulator), flow and liquid level alarm
Overvoltage protection: sensor, 4-20mA and AC power input
Working temperature (electronic): -5 to 140 ℉ (-20 to 60 ℃)
Weight: 4.5kg
QZ-A electrode
Flow velocity measurement range: 0.03-6.2m/s
Liquid level measurement range: minimum head: 25.4mm. maximum head: 4.57m
Working temperature: 5 to 150 ℉ (-15 to 60 ℃)
Exposed materials: PVC, epoxy resin, polyurethane
Sensor cable: 7.6m long immersed polyurethane protective shell, shielded, 3-axis
Electrode installation components: including MB-QZ stainless steel installation bracket
Temperature compensation: automatic, continuous

Available for selection
Data logger: programmable, with a storage capacity of up to 50000 pieces of data, recording time and date or recording total amount, average value, maximum value, and instantaneous time in the form of process reports. Including RS232 data interface, connecting cable, and Windows software
Sensor cable: 15m long RG62AU coaxial cable connecting electrode or bonded to 150m
Sensor cable junction box: made of steel, waterproof NEMA4 protection level, connected to terminal interface.
Input power supply: 200-250VAC 50/60Hz, 12VDC or 24VDC
Heater protection: Constant temperature control - * Temperature below 0 ℃
Intrinsic safety isolation barrier: allows electrodes to be installed in hazardous locations of Class I.II. III. Div. I, II, Group C, D, E, F, G.
Sensors: Separated non-contact ultrasonic liquid level sensor and QZ-B flow rate sensor