Pfeiffer gas mass spectrometerIntroduction:

OmniStar/ThermoStarTop of the line gas analysis system, suitable for qualitative analysis, quantitative analysis, atmospheric sampling of various gases. The capillary tube can be heated and temperature controlled to ensure the smooth transfer of the sample gas to the mass spectrometer and avoid the influence of water vapor on analysis. High detection sensitivity and accuracy.
Mass spectrometerApplication Example 1 of Omnistar/ThermoStar: Combination of Differential Reactor and OmniStar


Differential reactor is a gas experimental system that customers can configure according to their own experimental needs, in conjunction with PFEIFFERmass spectrometerThe main purpose of using OmniStar is to analyze the content of nitrogen oxides and ammonia in experiments, in order to determine the amount of gas changes in the reaction.
Mass spectrometerApplication Example 2: BEL-CAT Adsorbent Instrument Combined with OmniStar

Catalyst analyzer BEL-CAT and PFEIFFERmass spectrometerOmniStar is used to measure the surface acidity of adsorbent materials. Adsorption experiments are conducted based on temperature changes and changes in NH3 TPD/TPR content. The ammonia content is determined by measuring the peak value of ammonia changes using mass spectrometry.
Mass spectrometerOmnistar/ThermoStar Application Example 3:
ThermoStar application in TA/TGA thermogravimetry analysis

Thermogravimetric analysis (TGA) is used to determine the decomposition temperature, decomposition rate, and thermal stability of materials.
When a substance is heated, it undergoes chemical reactions or decomposition, and its quality changes accordingly. By measuring the changes in the quality of a substance, the process of change can be studied. ThermoStar can connect capillaries through TGA interface and use synchronous software to analyze the complex gases emitted after combustion.
Pu Fa, represented by Shanghai Bodong AgencyMass spectrometerOmnistar combined with TGA thermogravimetric analyzer
Thermogravimetric Analysis (TG or TGA) is a technique used to study the thermal stability and composition of materials by measuring the relationship between the mass and temperature changes of the sample under program controlled temperature. Thermogravimetric analysisMass spectrometry analysisThe method can study the changes in crystal properties, investigate the thermal stability, decomposition process, dissociation, oxidation-reduction, quantitative analysis of composition, moisture and volatile compounds, reaction kinetics and other properties of substances.
German Pfeiffer represented by Bodong onlineMass spectrometerOmnistar, when used in conjunction with a thermogravimetric analyzer, can not only obtain thermal analysis information, but also further detect the escaping gases during the thermal analysis process, obtaining more chemical information about the material. due tomass spectrumThe combination of mass spectrometry and thermogravimetric TG-MS has become an important means for quality control, product safety, and product development, as it can detect very low levels of material content.
Shanghai Bodong Customer Case: A Research Institute of the Chinese Academy of Sciences
This system is used to detect low levels of residual solvent dichloromethane in a drug target substance, and to identify mixed solvents at the same temperature. The single TG weight loss is composed of water, ethanol, and acetone.
Thermogravimetric analysisMass spectrometry analysisSystem configuration:
1. Temperature range: 20 ℃ -1000 ℃
2. Heating and cooling rates: 0-100 K/min
3. Cooling time: 10 minutes
4. Weighing range: 2000 mg
5. Measurement atmosphere: dichloromethane, water, ethanol, and acetone.
6. Mass flow meter
7. Vacuum sealed structure, with a vacuum degree of up to 10-2 mbar
Shanghai Bodong Germany PfeifferMass spectrometerOmnistar configuration:
1. Measurement range: 1-300 amu
2. Injection method: atmospheric pressure injection
3. Heating temperature: 1-350 ℃
4. Capillary material: Quartz capillary

PfeifferMass spectrometer Collaborating with friendly factories in the UKHiden,AmericaAmetekmass spectrometerCompared to the main advantages:
1. Whole machine design: The entire mass spectrometer adopts a fully enclosed structure to protect the cleanliness of all components inside the instrument, prevent interference in measurement, and ensure high sensitivity, ensuring that all components are imported from Europe.
2.Mass spectrometerAdopting gas tight closed ion source, dual filament design, advanced field axis technology and bias technology to ensure low gas release, low gas consumption, low background noise, high signal-to-noise ratio and other advantages.
3. Configure dual diversionTurbo Molecular PumpHipace 80, No need to add a bypass exhaust system,molecular pumpThe speed reaches up to 90000 rpm/min, the highest in the industry
4. Built in platinum micropores, capillary injection system, maximum temperature tolerance of 350 degrees, capable of achieving 5x10-3 mbar vacuum injection
5.Mass spectrometerBuilt in QuadstarTM software: easy to operate, powerful, and convenient for qualitative and quantitative analysis as well as online and offline analysis.