Ammonia gas detector

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The RS-2021 series fixed ammonia gas detector will sound and light an alarm when the on-site gas concentration leaks to the set alarm value. In addition, the detector also has functions such as real-time data display and transmission of detection concentration signals. The gas detector has one relay (switch signal) inside, which can control external devices such as sound and light alarms, fans, solenoid valves, etc. The standard signals output by the gas detector include voltage signals (such as 0-5/10V), current signals (such as 4-20mA), and standard digital signals (such as bus RS-485, RS2)

Product Details

RS-2021 seriesAmmonia gas detectorIt can continuously detect the concentration of ammonia gas and is suitable for on-site detection of hazardous gases in explosion-proof, toxic gas leak rescue, underground pipelines or mines. This instrument uses imported detection components with high sensitivity and good repeatability; Can set high and low alarm points, two-level alarms, and display alarm categories on the screen; Sensor fault self check, battery undervoltage prompt; Password management function, important operations require password verification to effectively prevent accidental operations; The testing program is controlled by an artificial intelligence microcomputer, with a reasonable workflow, simplicity and convenience, complete functions, and multiple adaptive capabilities.

RS-2021 series fixed typeAmmonia gas detectorWhen the gas concentration on site leaks to the set alarm value, the on-site sound and light alarm will give an alarm prompt. In addition, the detector also has functions such as real-time data display and transmission of detection concentration signals. The gas detector has one relay (switch signal) inside, which can control external devices such as sound and light alarms, fans, solenoid valves, etc. The standard signals output by the gas detector include voltage signals (such as 0-5/10V), current signals (such as 4-20mA), and standard digital signals (such as bus RS-485, RS2)

Technical Specifications

1. Gas detection: ammonia gas

2. Sensor: measuring toxic electrochemistry/measuring combustible catalytic combustion

3. Detection range: 0-100% LEL/0-100ppm

4. Resolution: 1% LEL/1PPM/0.1PPM

5. Alarm points: low and high alarm levels

6. Detection method: natural diffusion type

7. Detection accuracy: ± 5% F.S

8. Explosion proof grade: Exd II CT3

9. Protection level: IP45

10. Response time: ≤ 30s

11. Temperature range: -20 ℃ -60 ℃

12. Humidity range: ≤ 95%

13. Alarm mode: three-level alarm of sound, light, and vibration

14. Alarm volume: ≥ 75dB