Agilent7820AIntroduction to Gas Chromatography
Product name: Gas chromatograph
Model:7820A
Manufacturer:AgilentAgilent
Practical choices for routine analysis
7820AGas chromatography systems provide excellent gas chromatography analysis performance for all routine applications, including those that must comply with regulatory requirements.
Agilent 7820 GCKey Features:
1Equipped with an intuitive user interface and only five control buttons for the ammonium key, the gas path adjustment does not require the use of a pressure gauge or manual gas control knob. It is available in the system While improving overall performance, it also reduces the possibility of operational errors
2Use fully electronic gas path control on all injection ports and detectors(EPC)— Ensure better reproducibility of retention time and peak area, as well as reliable accuracy and precision.
3By setting the gas flow rate through software, you can save all important parameters of the analysis method. Digital circuits ensure that the set values between different operators are maintained during each operation*
4Standard high-precision injection port
1)Diversion/splitless(SSL)The injection port is suitable for large-diameter columns and all capillary chromatography columns
2)Filling column blowing injection port(PPIP)Suitable for large-diameter capillary columns and packed columns
5Automatic valve control
For the application in the petrochemical industry,7820AThe gas chromatography system can automatically control up to two heating valves
6Agilent's highly sensitive detectors are suitable for various samples
1)Flame ionization detector(FID)— The wide dynamic response range improves quantitative accuracy and is suitable for analyzing samples with high or low concentration components, reducing sample preparation requirements
2)Nitrogen and phosphorus detector(NPD)— For phosphorus or nitrogen-containing compounds, such as pesticide residues in food and environmental samples, it has excellent sensitivity and selectivity
3)Thermal conductivity detector(TCD)— Monofilament design provides lower noise and higher sensitivity for conventional analysis
4)Microcell electron capture detector(Micro-ECD)— Combining exceptional sensitivity, linearity, durability, and reliability
— If your laboratory analyzes halogenated organic compounds such as pesticides, polychlorinated biphenyls, and chlorinated solvents, this detector is your ideal choice
7, Used in conjunction withEZChrom Elite CompactSoftware that can be easily implemented in the laboratory7820AAll functions of gas chromatography system, this software is a fast and powerful chromatographic data system, including advanced data processing, flexible report editing, and all functions available from modern chromatographic workstations
8Adopting Agilent7693AAutomatic sampler, which has up to16a2mLsample vial
Agilent 7820ATechnical parameters of gas chromatograph:
performance metrics
Safety and regulatory standards
safety standards
? Canadian Standards Institute(CSA):C22.2 No. 61010
?CSA/Testing laboratory(NRTL):UL61010
? International Electrical Commission(IEC):61010
? European standards(EN):EN61010
Compliant with the following electromagnetic compatibility(EMC) Interference with radioactive frequencies(RFI)Regulations
?CISPR 11/EN 55011:1class, Alevel
?IEC/EN 61326
Design and manufacturing followISO 9001Quality system. can provideISO 9001Certification certificate.
Overall system performance*
* Use withEPC(Non diversion mode), automatic sampler, and Agilent data system7820AAnalyze tridecane(2 ngInjection volume).
The results may vary when using other samples and conditions.
Retention time repeatability:<0.06%
Peak area repeatability:<2%
Power requirements
?100 V(10%,–10%)
?120 V(10%,–10%)
?200 V(10%,–10%)
?220 V(10%,–10%)
?230 V(10%,–10%)
?240 V(10%,–10%)
? frequency47.5~63 Hz
?100 V, Power1500 W(The largest); Other voltages, power2250 W(The largest)
column oven
? Size:28.0 x 30.5 x 16.5 cm
? Operating temperature: above room temperature8 °Cto425 °C
? Temperature setting resolution:1 °C
? Maximum heating rate:75 °C/min(See table)1)
? Zui Long Run Time:999.99 min
? Program heating order:5
? Temperature fluctuations: changes in ambient temperature1 °C,Temperature variation of column temperature box< 0.01°C
– Column box temperature gradient:~ 2%
– Program heating repeatability:~ 1%
heating zone
? Independent heating zone, without column temperature box:5Two for the injection port and two for
Detector, and an auxiliary)
? The highest operating temperature for the auxiliary heating zone:350 °C
Supports up to two heating valves
Electronic pneumatic control(EPC)
? All injection ports and detectors are electronically controlled
injection portEPCmodule
? The pressure setting value and control accuracy are0.01 psi
? Accuracy of flow sensor:<±5%
detectorEPCModule accuracy:<Setting values8%
injection port
? Install two injection ports simultaneously
? Configurable injection ports:
– Blow and fill the column injection port(PP)
– diversion/Non diverting capillary injection port(S/SL)
Blow and fill the column injection port
? Electronic flow control
? Zui High Operating Temperature400 °C
? Maximum traffic:< 100 mL/min
? The adapter can be used for1/4Inches and1/8Inch filled column, and0.530 mm
capillary column
diversion/Non diverting capillary injection port(S/SL)
? Electronic pressure/flow control
? Zui High Operating Temperature400 °C
? Pressure range:0 to60 psi
? Maximum diversion ratio:250:1
? Total flow setting range: For nitrogen:0 to200 mL/minForH2orHe:
0 to500 mL/min
detector
All detectors use electronic gas path control for gases(EPC). Can install two at the same time
A detector.
Available detectors
? Flame ionization detector(FID)
? Thermal conductivity detector(TCD)
? Electron capture detector(ECD)*
? Nitrogen and phosphorus detector(NPD)
FID
? Electronic pressure/flow control
? Zui High Operating Temperature425 °C
? Zui small detection limit(MDL):< 3 pgcarbon/s, measured with tridecane
? Linear dynamic range:> 107, usingN2Carrier gas,0.29 mmInner diameter nozzle
? Zui Big Data Collection Rate100 Hz
TCD
? Electronic pressure/flow control
? Zui High Operating Temperature400 °C
? Zui small detection limit(MDL):< 800 pgpropane/mL, usingHeCarrier gas (experimental)
The indoor environment may affectMDL)
? Sensitivity:>80000 mV?mL/mg
? Linear dynamic range:105 (±10%)
ECD*
? Electronic pressure/flow control
? Equipped with hidden anode and high flow rate for anti pollution
? Zui High Operating Temperature400 °C
? Tail blowing: argon gas/5%Methane or nitrogen
? Radioactive Source:< 15 mCi 63Ni
? Zui small detection limit(MDL):< 0.02 pg/mLLin Dan
? Dynamic range:> 104, determined by Lindane
? Zui Big Data Collection Rate50 Hz
*Not provided in JapanECD
NPD
? Electronic pressure/flow control
? Zui High Operating Temperature400 °C
? Zui small detection limit(MDL):< 0.4 pg N/s, < 0.2 pg P/sUsing azobenzene/
Mixture determination
? Selectivity:25000 to1 gN/gC, 75000to1 gP/gCUsing azobenzene/horse
Determination of sulfur phosphorus mixture
? Dynamic range:> 104 N, > 104 PUsing azobenzene/Mixture determination
? Data collection rate: up to100 Hz
Optional automatic liquid sampler(ALS)
Support oneG4513AAutomatic sampler, with a capacity of16A sample bottle
data communication
? Equipped with one analog signal output channel as standard(1 mV, 1 Vand10 VOutput)
? remote start/停止
? Local Area Network(LAN)