We provide you with safe and energy-saving solutions. Equipped with a fan and high-efficiency molecular filter device; During the experiment, the fan extracts toxic and harmful reagents emitted during the operation of the cabinet and brings them to the filter device. After being filtered by a high-efficiency molecular filter, the clean gas is directly discharged into the laboratory, and the toxic and harmful gases are intercepted by the molecular filter. The air that comes out is clean. Because there is no need for external discharge, it saves 100% energy consumption. In addition, it is placed directly on the laboratory countertop, avoiding expensive and cumbersome pipeline engineering.

Product Details

633 SMART air purifying fume hood: safer to operate, easier to use, using intelligent new technology to purify laboratory air while keeping track of equipment operation, timely alarms, and proper handling!

净气型通风柜

Easy to use

Through a fume hoodThe flashing of the halo is used for information transmission, indicating the current operating status. When the halo is stable, it indicates that the current fume hood is operating normally. When the halo flashes, it is an alarm. Different alarm sounds have different warning situations, such as abnormal surface wind speed; Fan malfunction; Filter saturation;

EGuard applicationTo achieve remote online monitoring of your fume hood status, program settings can be made, and in case of unsafe situations, timely alarm reminders can be sent on your mobile phone, tablet, and computer.

Safer operation

The top flexible modular filtration system can filter different substances such as gases, powders, and mixtures of gases and powders. After being filtered by the filtration system, clean air circulates indoors, effectively protecting the laboratory and laboratory personnel. Follow the filtration requirements (Level 1 and Level 2) in Chinese standard JG/T 385-2012, American standard ANSI Z9.5-2012, and French standard AFNOR NFX 15-211. A new type of filter alarm for detecting organic solvents, inorganic acids, and formaldehyde. A new electronic speedometer for monitoring surface wind speed. Elab Safety Process ESP: Conduct a suitability safety assessment on each product before use based on a questionnaire from Elab R&D and Application Laboratory.

633 SMARTClean air type fume hoodRegistered filter loop system!
Two layers of identical filters are installed in the filtration system. One floor is located above the fan system, and the other floor is located below the fan system; When the lower filter is saturated, the upper filter can continue to perform its filtering function. This design ensures that even if the lower filter is saturated, no chemical gas will leak into the room.

Security Alert

Registered intelligent technology passedLEDThe flashing of the light strip and the frequency of the alarm sound are used to remind the following situations: fan failure, abnormal surface wind speed, or filter saturation

eGuardsoftware:Remote real-time monitoring of fume hood status, changing settings, and obtaining user usage records can be achieved through smartphones or computers

Follow safety standards:ChinaJG/T 385-2012Standard; France:AFNOR NF X 15-211:2009Standard; britain:SEFA 9 : USA - BS 7989Standard; Germany:DIN 12 927Standard;CELabel:EN 1822 : 1998 (HEPA H14)andULPA U17filter)

face velocity: 0.4m/s-0.6m/s(Compliant with safety standards)

anemometer: Real time monitoring of wind speed at the operating port, with a normal value of0.4-0.6 m/sIf the face wind speed * is at a lower value, it meansH14Or the pre filter may be blocked or the fan may malfunction

Cabinet control concentration:According to the United StatesASHRAE 110Testing method, detectedSF6The leakage is lower than0.05ppb(Compliant with safety standards)

filtration efficiency:The filtered chemical gas concentration is lower thanTWAvalue1%(Compliant with safety standards)

Filter automatic alarm: Molecode S:Saturation detection for organic compounds;Molecode A:Saturation detection for inorganic substances;Molecode F:Saturation detection for formaldehyde

Filter adsorption capacity: The Elab Chemicals Handbook lists over600Chemical filtration parameters:inTWAof1%Critical point, the specific mass of the chemical adsorbed by the filter

Test Certificate: Tianxiang Report (based on France)NFX 15-211standard), SGSReport (based on the United States)SEFA 9standard),Tongji University Report (based on China)JG/T 385-2012standard)

fluorescent lamp: high qualityLEDfluorescent lamp500lux (IP 67)

Types of activated carbon molecular filters: GF4 AS:Organic based(Inorganic second)GF4 BE+:Organic and inorganic gases; GF4 F:formaldehyde GF4 K:ammonia

Efficient particle filter: HEPA H14Efficient particle filter: ensuring that for particles with a diameter greater than or equal to0.3µmThe particle filtration efficiency has reached99,995%According toEN1822-1in the standardMPPSThe testing methodULPA U17Ultra efficient particle filter: ensuring particle size greater than or equal to0.3µmThe particle filtration efficiency has reached99,995%According toEN1822-1in the standardMPPSThe testing method

Pre particle filter: Regarding particle size>0.3MmThe particle filtration efficiency is40%

Ergonomic design!
The tilted design of the front panel makes the operator more comfortable and provides a better view of the operation.
The oval and trapezoidal operation holes allow the operator's arms to move freely inside the cabinet, and the * protective area on the front panel provides safety to prevent chemical splashes.
The curved design of the front edge of the countertop provides comfortable arm support.

633 SMART air purifying fume hood

-----Easy to install!

After receiving the goods, it only takes about 30 minutes to install a Kai Pu Tai product. After assembly, plug in the standard power socket and the fume hood can be used immediately.
------Provide safety protection for any workplace!
Kaipu Tai SMART can be installed at any location in the laboratory to provide safety protection for chemists. As they do not need to exhaust indoor air, even if multiple units are installed, there is no need to worry about the supply of fresh air in the laboratory.
------No consumption of air conditioning air!
Installing a Keppel SMART in an air-conditioned room can help save a lot of energy as it does not require expensive air conditioning fresh air to be discharged. The cost of a filter used for one Keppel SMART fume hood per year is much lower than the air conditioning consumption cost of traditional fume hood systems. Saved at least 85% of air conditioning consumption.
------Environmental protection!
During chemical operations, the filter will effectively filter out chemical gases, avoiding their overflow. The use of Keptek SMART can protect the outdoor environment of laboratories, such as offices or nearby buildings. With certain guidance, chemists can minimize the volatilization of chemical reagents as much as possible, and more operations can be carried out inside Keptek fume hoods.


Through a fume hoodContribute to environmental protection!

Standards and certifications:
Adhere to the strict filtering standard NFX 15-211
SGS and Tianxiang certification reports! report

Technical Specifications: