50-300 ultrasonic water meter

NegotiableUpdate on 06/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

50-300 ultrasonic water meter

Product Details


Product Features
(1) This flow sensor adopts ultrasonic flow sensing method. Accurate measurement, not affected by rust in water and external magnetic field interference, suitable for Chinese water quality. The shell is forged by hard molds, processed by CNC machine tools and combination machine tools, with good mechanical strength and high dimensional accuracy. Ensuring the stability and accuracy of the product's long-term operation.

(3) It has self diagnosis, fault display, and power-off data protection functions. When the ultrasonic water meter accidentally malfunctions, it displays a fault code and automatically saves the current data.
(4) Adopting LCD display, displaying complete and accurate data, and reading data conveniently and quickly.
(5) Real time clock design to achieve date recording and display functions.
(6) Adopting environmentally friendly lithium batteries, the battery has a service life of over 6 years (theoretically calculated to be greater than 10 years).
(7) Integrated structure, beautiful appearance, display can rotate horizontally and flip vertically, easy to read; Single key design, easy to operate, convenient to install.
(8) There is an MBUS bus interface inside, which is used to achieve remote data collection.
(9) Easy to install and maintain, with dust-proof, moisture-proof, anti disassembly, and anti human damage functions.
3. Main technical parameters

index Water meter parameters
Nominal diameter DN (mm) 50 65 80 100 125 150 200 250 300
accuracy class Level 2 (CJ128-2007)
flowmeter
Common flow Q3 (m3/h) 25 40 63 100 160 250 400 630 1000
Boundary flow Q2p (m3/h) 0.2 0.32 0.504 0.8 1.28 2 3.2 5.04 8
Minimum flow Q1 (m3/h) 0.125 0.2 0.315 0.5 0.8 1.25 2 3.15 5
measured media Water, uniform liquid, and fill the tested pipeline
Range ratio R200
Maximum allowable working pressure 1.6MPa
work environment -25℃~55℃,≤100%RH
Temperature rating T30
Categories of climate and mechanical environmental conditions Class C
Electromagnetic compatibility level E1
LCD display (8-bit, decimal)+special symbol
Data communication interface M-Bus、485
Built in battery lifespan 3.6V high-energy lithium battery
4. Display content
(1) In the main display function, press the button for 6 seconds to enter each sub display function
(2) Enter the sub display function, press the key for 6 seconds to enter the next sub menu, P1-P2-P3-P4-P1... loop.
(3) P2 sub loop display content: calculator calibration and internal parameters.
(4) P4 sub loop display content: historical data
(5) P3 sub loop display content: flow and heat verification
(7) When the battery level is too low, an alarm symbol "" will be displayed in the upper right corner of the screen.
(8) 50 minutes without button action, the power-saving display mode intermittently displays' accumulated traffic '.
Table p1: Main Loop Display Content

show contents unit describe
1 Traffic m 3 For meter reading purposes
2 Accumulated working time h Accumulated time of electricity on the meter
3 Year Month Day
4 Instantaneous flow rate m 3/h
5 table number
6 System Voltage
Table p2: Sub loop Display Content (1 for Calculator Identification)
show contents unit describe
1 Hour minute second current time
2 Table coefficient
3 Table coefficient
4 Table coefficient
5 Table coefficient
6 Table coefficient
7 Table coefficient
8 Table coefficient
9 Table coefficient
10 Table coefficient
11 dynamic parameter
12 dynamic parameter
13 dynamic parameter
14 dynamic parameter
15 VERSION
Table P3: Sub loop Display Content (Historical Data)
show contents unit describe
1 Historical year month this month
2 Display the monthly cumulative traffic of the month m 3
3 Historical year month Last month
4 Display the monthly cumulative traffic of the month on the screen m 3
5 Historical year month Last February
6 Display the monthly cumulative traffic of the month on the screen m 3
35 Historical year month Last 18 months
36 On screen display, monthly cumulative traffic m 3

5. Data storage: Accumulated traffic, historical data, fault information, and accumulated working time are written to internal flash memory every 24 hours, and power-off status data is saved for more than 10 years. Automatically record the cumulative traffic of the current month at the end of the month, and save the monthly cumulative traffic of 18 months of historical data.
6. Installation and use:
(1) The selection of specifications for ultrasonic water meters should be based on the actual flow rate of the pipeline being equal to or slightly lower than the commonly used flow rate of ultrasonic water meters, and the diameter of the ultrasonic water meter should not be determined solely by the diameter of the pipeline.
(2) During installation, the direction of the arrow on the watch case is the same as the direction of the water flow.
(3) After installation, lead seals should be applied between the ultrasonic water meter body and the connecting nut, as well as between the temperature measuring ball valve and the temperature sensor.
(4) All components of the ultrasonic water meter (flow meter components, temperature sensor components, and calculator components) should be installed in positions that avoid exposure to sunlight Water flooding Frozen Chemical pollution, and convenient disassembly and meter reading.
(5) Users can refer to the installation diagram.
(6) During the construction of the water supply system, a straight pipe section should be installed first to replace the ultrasonic water meter for pipeline cleaning. Before installation, the system pipeline should be thoroughly cleaned to remove debris such as hemp fibers and sand from the branch pipes, in order to avoid flowmeter failure; When using, the filter should be cleaned regularly (recommended once a year) according to the water quality to remove debris. It is recommended to leave a 5DN straight pipe section in front of the meter and a 3DN straight pipe section behind the meter (DN is the nominal diameter of the ultrasonic water meter).
(7) If the operation time of the ultrasonic water meter reaches 8 years (2 calibration cycles) or the display screen shows a battery alarm symbol, specialized technicians should replace the battery to avoid affecting the normal operation of the ultrasonic water meter.