High resolution liquid chromatography-mass spectrometry has the following advantages:
Date: 2022-04-07Read: 1
thermoHigh resolution liquid chromatography-mass spectrometryMultiple MS/MS scanning modes can be provided. Choose reaction monitoring mode or multi reaction monitoring, with * sensitivity and selectivity, to meet the high requirements of complex matrix sample analysis. Neutral loss scanning, mother ion scanning, and combined scanning modes can improve analytical sensitivity and information specificity in high-throughput structural identification. At the same time, it provides the function of automatically developing MS/MS methods, without the need to rely on experience to explore the conditions of MS/MS. The workstation automatically captures sub ions and optimizes their CID energy, providing an automatic fragmentation curve that can be directly used for MS/MS analysis. Especially suitable for workers who are new to mass spectrometry analysis.

Has the following advantages:
1. CDS calibration liquid transmission system:
Through CDS-9030, quality calibration standards can be injected through a secondary probe independent of the main probe, which is built into an optional secondary ion source interface. The secondary ion source interface can be compatible with various ion sources and achieve one click installation. By preparing two probes, one for analysis and the other for quality calibration, both analysis and quality calibration can be performed without worrying about pipeline contamination.
2. Inheriting the advantages of Thermo:
Inheriting the technology of high-sensitivity thermo high-resolution liquid quality. In addition, the instrument also inherits the characteristics of simplicity and ease of maintenance. Standard ESI ion source, optional APCI or DUIS ion source. Like Thermo high-resolution liquid chromatography, both ESI and DUIS ion sources use auxiliary heating design. Like Thermo high-resolution liquid, each type of ion source adopts a cable free and pipeline free design, making it easy to quickly switch between different ion sources.
3. The only all Chinese high-resolution liquid chromatography-mass spectrometry (LC-MS) instrument on the market:
The control and data processing workstation of the high-resolution liquid chromatography-mass spectrometry system is LabSolutions LCMS, which is the same as the mass spectrometry workstations used by Thermo's other high-resolution liquid chromatography-mass spectrometry systems, and all interfaces from parameter settings to help menus are in Chinese. This means that accurate quality analysis can be conducted using the same operational style as before. Provide five analysis modes: MS, MS/MS, MRM, MS/MS (DDA *), and SIM. In MS/MS, MRM, and MS/MS (DDA) modes, the mass range of the quadrupole mass separator can be freely set by the user, and the analysis conditions can also be customized. It can meet different analysis needs of customers, including various analyses from conventional qualitative and quantitative analysis to customized analysis.