OM-5 two-component acid resistant and anticorrosive coating
High temperature acid resistant and anti-corrosion coating
OMType I acid resistant and anti-corrosion coatings are all two-component, and can be divided into two types according to their different parts of use: Type I and Type II. The main agent is stored in iron drums with a net weight per drum17Kg, resin curing agent is packaged in small plastic pots, with a net weight per pot1kg . During construction, fully open the lid of the main agent iron drum, slowly add a pot of curing agent and stir continuously until there are no bubbles and it is evenly mixed. The prepared coating should be3Used up within hours.
The thickness of the coating has been adjusted before leaving the factory, and the general base material is35~45SThe fabric is45~55S(Apply)-4If adjustment is needed for viscosity measurement, dilute with diluent, and the storage period of the coating should not exceed nine months.
Main performance and indicators
Surface drying time <4Hour by hour
Storage time at room temperature >270sky
heat resistanceType I250℃(1Hour) Type II150℃(1Hour)
Corrosion resistanceType I40%H2SO4At room temperature30Oh my god,80℃15sky
Type II30%H2SO4At room temperature30Oh my god,80℃15sky
Bonding force with concrete >1.0Mpa
Type I and Type II coatings are generally applied by brushing method, and there is no strict requirement for the dryness and wetness of the concrete cylinder wall during brushing. It is suitable for construction at any time after the final setting of the concrete, but the brushing surface should be basically flat. For example, when painting oil hemp surface or small bubbles, it should be applied in advance107Scrape the adhesive cement putty flat(5A portion of cement 1copy107glue After the surface treatment of the concrete with an appropriate amount of water, the bottom layer coating can be applied immediately. The bottom layer and surface layer coatings should be applied separately, and it is strictly prohibited to apply the bottom layer and surface layer continuously without stopping. There must be a drying time interval in between, and the temperature of the construction site should be controlled according to the table below
Temperature(℃)5below5-15 15-30>30
Interval time(h)Not suitable>6 >4 >2
The number of coats is generally one bottom and two sides, with a total thickness of about0.8-1mmThe amount of paint used per square meter is approximately1About kilograms.
When brushing, the dipping material should not be too much at once, and the soaking material of the brush should not exceed half of the brush hair length. It is required to apply even force. After brushing, the tools should be cleaned with thinner in a timely manner, and all tools and containers should not come into contact with water. When the weather is dry and the temperature is high, the brush should be cleaned with thinner once every hour to prevent the bristles from sticking. When brushing, it should be done in a criss cross pattern, with one brush for each direction.
OM-5The high-temperature, acid resistant, and anti-corrosion coating for the chimney is based on the specific situation mentioned above. Our factory referred to relevant scientific research results in China and, with the support and cooperation of experts from the Ministry of Metallurgy, conducted comprehensive adaptability tests after nearly two years of formulation modification and exploration, combined with the operating conditions of the power plant.
OM-5The high-temperature, acid resistant, and anti-corrosion coating for the chimney has been preliminarily recognized by the design and construction units, and has been approved by the Northeast Baishan Thermal Power Plant210MInternal anti-corrosion of steel chimney, Erdaojiang Power Plant in Jilin Province180MInternal and external anti-corrosion of steel chimney, Shanxi Yangquan Sunshine Power Plant240MThe anti-corrosion renovation of the inner side of the old single tube reinforced concrete chimney and the new reinforced concrete sleeve chimney of Guigang Power Plant in Guangxi are adopted. (Previously, the Hequ Power Plant in Shanxi Province, Nayong Power Plant, Qianxi Power Plant, Yemazhai Power Plant, and Pannan Power Plant in Guizhou Province were also used by design units.).
Supply epoxy anti-corrosion paint, polyurethane acid resistant anti-corrosion paintG-2New polymer anti-corrosion coatingsIBN8710Interpenetrating network anti-corrosion coating, aviation sign paint, road reflective paint, luminous paint, fluorescent paint, latex paint for interior and exterior walls, fluorocarbon paint for steel structures, fluorocarbon exterior wall paint, organic fireproof blocking material, fireproof package, ultra-thin steel structure fireproof coating, inorganic fireproof board, etc
Steel structure fireproof coating is a functional coating that protects steel structures. Nowadays, in building construction, in order to make the building more beautiful, some decorations are often made on the steel structure. However, decoration can lead to problems. How can we ensure that the steel structure fireproof coating applied is not damaged? Even if it is damaged, how should it be repaired? Steel structure fireproof coating is formulated according to the fire resistance rating required by the design, and the thickness and fire resistance time of the coating are corresponding. If the coating falls off or is damaged during decoration, it will affect the fire resistance limit of the steel structure; In addition, during decoration, the steel structure needs to be connected, reinforced, and installed, which can cause the fireproof coating at many welding points to expand or carbonize.