For flow meters, the level of energy consumption depends on the pressure loss of the flow meter. Energy consumption with high pressure loss
Large, low pressure loss, and low energy consumption. Due to the widespread use of orifice plate instruments in the metallurgical industry, the orifice plate and V-cone are discussed below
Compare the pressure loss and examine the magnitude of energy consumption during the measurement of flow rate between the two.
Example 1: Measurement of saturated steam flow in a certain factory, with a pipeline inner diameter of 257; Working absolute pressure 0.9MPa; Operating Temperature
175.35℃; Density 4.655kg/m3; High flow rate of 30t/h; The commonly used flow rate is 20t/h.
The orifice plate and V-cone have the same β=0.6.
The calculation results are as follows (refer to the CD material for the calculation formula and process):
When the common flow rate is 20t/h, the pressure loss of the orifice plate is 14.162kPa
The pressure loss of the V-cone is 6.523kPa
The pressure loss of the orifice plate is 7.639kPa greater than that of the V-cone. Under the same flow rate conditions, the orifice plate has a higher pressure loss per hour than the V-cone
The excess energy consumption is 11.395kWh. If based on the current industrial average electricity cost of 0.8 yuan/(kW. h), the annual electricity cost is calculated based on driving
After 300 days of calculation, only one set of orifice flow meters will incur additional electricity costs per year compared to V-cone flow meters
0.8 (yuan) x 11.395 (kW/h) x 24 (hours) x 300 (days)=656300 yuan
Example 2: Blast furnace gas, inner diameter of pipeline: 702.4mm, working pressure (G): 12kPa, temperature: 70 ℃,
Local atmospheric pressure: 98.39kPa, working density of 1.0326kg/m3, commonly used flow rate of 25000m3/h
The orifice plate and V-cone have the same β=0.6955. The calculation results are as follows:
The pressure loss of the orifice plate under common flow rate is 1.894kPa
The pressure loss of the V-cone is 0.479kPa
The pressure loss of the orifice plate is 1.415kPa greater than that of the V-cone, which consumes more energy per hour under the same flow conditions
12.283kW/h。 According to the industrial electricity cost of 0.8 yuan/(kW. h), calculated based on 330 days of driving per year, there is only one set of holes
Plate flow meters will incur additional annual electricity costs compared to V-cone flow meters
0.8 (yuan) × 12.283 (kW/h) × 24 (hours) × 330 (days)=778300 yuan
From the above calculations, it can be seen that a small set of flow meters that we usually do not pay attention to, when selecting
What type of instrument has such great potential (or such great waste that has not been discovered) to explore
The energy-saving effect of V-cone flowmeter is very significant. Currently, there is insufficient supply of electricity and energy in our country
In this case, using energy-saving flow meters not only creates profits for the enterprise itself, but also conforms to the advocated energy-saving reduction
Industrial policies for scheduling.