Brief Introduction

The difference between air-cooled and water-cooled high and low temperature humid heat chambers

Many users are unsure whether air-cooled or water-cooled humidifiers are better when choosing between high and low temperature humidifiers? In fact, there is no superiority between water-cooled and air-cooled cooling methods, and there are solutions to all the negative factors. Users make their choices based on their own resources, on-site environment, price, and actual needs. Below, we, Hubei Gaotian, will explain in detail the differences between the two heat dissipation methods.

Air cooled high and low temperature humid heat chamber: It uses the circulation of air to dissipate heat. The main refrigeration components consist of fins, light pipes, and cooling fans. The advantage lies in the production cost, as well as the convenience and speed of installation and debugging. The adverse factor is that it is greatly affected by high temperature weather, especially during the summer months in the south when the room temperature exceeds35In the absence of air conditioning cooling, the ambient temperature of the site will increase during the use of the machine, resulting in slightly higher noise compared to water-cooled installation sites, as water-cooled installation sites are generally located on outdoor rooftops and floors. Air cooled equipment can move freely.

Water cooled high and low temperature humidity chamber; Use the cyclic fluidity of water to dissipate heat. The main components are from the water towerComposed of water pipes and water pumps, the advantage is that the cooling effect is less affected by high temperature weather, and the noise is low (the water tower is installed outdoors). The disadvantage is that it is greatly affected by low temperature weather (especially in winter in the north where the outdoor temperature is below minus zero), and the installation and commissioning time is longer than that of air-cooled type. The production cost is higher than that of air-cooled models.

The maintenance frequency depends on the environmental factors and frequency of the machine site, and is higher than that of air-cooled cooling systems because water-cooled cooling systems are installed in outdoor water towers. Water pipes are prone to impurities. Dirt.

The equipment movement of the water-cooled box requires reinstalling the water pipes and debugging, and the installation cycle should be based on the distance of movement1to5The sky doesn't wait. If the user has a high floor, they need to consider the safety issues of installation personnel, personnel involved in equipment maintenance, and equipment maintenance personnel.