Escape type respiratorIt can be divided into filtered self rescue respirators and chemical oxygen self rescue respirators. The working time of air respirators is generally 30-360 minutes, and the limit of protection time varies depending on the type of respirator.
Overall, the protection time of air respirators is slightly shorter than that of oxygen respirators.
1. Self contained compressed air breathing protection device, only used for escaping from hazardous gas areas. It shall not be used for firefighting, entering oxygen deficient compartments or cargo tanks, nor shall it be worn by firefighters.
2. The compressed gas cylinder of the escape breathing apparatus is equipped with a pressure gauge. During storage, the pressure gauge does not display the gas source pressure.
3. The escape breathing apparatus is equipped with a flame resistant hood that can cover the head, neck, and shoulders, with a clear, wide, and bright observation window on the hood.
4. Easy to operate, simply open the top cover of the gas cylinder valve without any additional actions.