Fire-fighting Anti-chemical ClothersUsing flame-retardant treated silk fabric, double-sided coated with flame-retardant and chemical resistant adhesive, the main material is made of adhesive tape that only produces carbonization when exposed to fire, does not dissolve normally, and maintains good strength. The main body of the clothing and gloves are made through the process of bonding, sewing, and pasting, and are matched with flame-retardant, chemical resistant, voltage resistant, and puncture resistant boots to form a complete set of clothing.
Fire-fighting Anti-chemical ClothersIt is one of the protective clothing for firefighters. It is the protective clothing worn by firefighters in fire and accident scenes with hazardous chemicals and corrosive substances to protect themselves from chemical hazards or corrosive substances.
Main technical parameters of firefighting and chemical protective clothing
Adhesive tape thickness: 0.45 ± 0.05mm
Tensile strength: warp and weft direction ≥ 450N/5cm.
Tear strength: ≥ 32N.
Anti acid and alkali penetration performance: 10mm liquid column lh does not penetrate.
Gasoline resistance: Soak 120 # gasoline for 30 seconds without cracking or sticking.
Flame retardant performance: flame retardant time ≤ 2s, flame retardant time ≤ 10s, damage length ≤ 10cm, no melt droplets
Performance of chemical resistant boots, electrical insulation performance of the sole: ≥ 5000V. Penetration resistance of the sole of firefighting chemical resistant clothing: ≥ 780N.
Waterproof performance of chemical resistant boots: soaking in water for 2 hours, no water leakage.
Performance sticker adhesion strength: ≥ 0.78kn/m
Anti water leakage performance; 5 3L/min nozzles shall be flushed for 15 minutes without leakage.
Overall weight ≤ 5kg
Precautions for the use and storage of firefighting and chemical protective clothing
(1) Firefighting and chemical protective clothing must not come into direct contact with flames and molten materials.
(2) Before use, it is necessary to carefully inspect the clothing for any damage. If there is any damage, it is strictly prohibited to use.
(3) When using, it is necessary to pay attention to the tight fit between the head mask and the face mask of the mask, and the large white buckle of the neck strap must be fastened to ensure that the neck is airtight. The belt must be tightened to reduce the "bellows effect" during exercise.
(4) After each use, wash with soapy water or 0.5-1% sodium carbonate solution according to the dirt situation, then rinse with clean water, place in a cool and ventilated place, air dry and pack.
(5) When folding, place the hood opening upwards on the ground. Fold back the hood, neck strap, and sleeves, then fold the garment vertically, overlapping left and right, with the tips of the two boots facing outward on one side. Place the gloves in the middle, roll the soles of the boots relative to each other to form a roll, and place them horizontally in the chemical resistant clothing packaging bag.
(6) Fire and chemical protective clothing must not be exposed to heat or sunlight during storage, and must not come into contact with active chemicals or various oils.
(7) The product has a shelf life of five years under storage conditions that comply with standard regulations.
(8) Airtight chemical protective clothing should be visually inspected every six months (six months) before each use and during storage. Conduct an air tightness inspection once a year.
(9) In the packaging box, it should be taken out for at least three months for a comprehensive visual inspection, then placed flat or hung, cooled down, and then folded and stored again. Chemical protective clothing should always be stored in a dry, clean, and pollution-free environment. Before storage, lubricate and open the zipper.